Rommel,
What the size of new impeller :
Do you have a flow meter after the valve?
Arturo Murillo
´Tuberías Visa de Culiacán.
Dear All,
I have commissioned a centrifugal pump months ago and here are the pump name plate 75ft TDH and 2000 gpm. The commissioning result are the following:
Suction pressure: 13 psi
Valve Shut Discharge pressure: 54 psi
Actual Impeller Diameter Base on submitted Pump Curve is: 10.2 inches
(base on the data gathered by valve shut delta pressure)
Final Discharge pressure: 39 psi @ 2000gpm or 60 ft TDH only (valve already adjusted to meet 2000 gpm requirement)
The problem is the pump did not meet its 75 ft. TDH, I contacted the supplier and opted to increase the impeller diameter.
Now when the new impeller was installed, I gathered the following:
Suction Pressure: 13 psi
Valve shut Discharge pressure: 56 psi
When we open the discharge valve the pressure is still the same (56 psi),
pressure gauge is calibrated and valve is functioning well. For me the
pressure should lower down to its operating limit prior to adjusting of
valve base on flow requirement. What seems to be the problem please
enlighten me. By the way the fluid is water.
Regards,
Rommel
Facilities Enginner
[Non-text portions of this message have been removed]