Re: Pump Commissioning

From: <Christopher>
Date: Fri May 19 2006 - 23:54:00 EDT


On May 19, 2006, at 7:05 PM, elie altawil wrote:

> I don't se any problem. Am I missing something?
As I read his letter I think he was wondering why he wasn't getting the full DHP along with the max flow. Sounds like he needs to do a little pump homework.
Christopher Wright P.E. |"They couldn't hit an elephant at <a href="/group/PipingDesign/post?postID=VSXE1ool8FdRSX9vndjEKbp5uYwl8gP-pzZ-QftAi88_xMk9eGuGD-fvwxmyErvl9w3yGRV22zEhz2NK">chrisw@skypoint.com</a> | this distance" (last words of Gen.

.......................................| John Sedgwick, Spotsylvania
1864)
<a href="http://www.skypoint.com/~chrisw/">http://www.skypoint.com/~chrisw/</a> Received on Fri May 19 23:54:00 2006