Re: Double Locking Trap Closure (i.e GD Engineering Bandlock 2)

From: <elie>
Date: Wed Dec 13 2006 - 09:01:00 EST


Mr. Satria,

   I believe the answer is ASME BPVC section VIII, but I am not 100% that there is no other code that cover this subject.

   I am also doing work for BP in Colorado, USA and I would appreciate a follow up if you find which code govern this issue.

   I have spec'd and installed several enclosures mostly Sentry and GDE Bandlock 2. I always spec'd them per ASME Sec. VIII, Div 1 for B31.3 plants.

   Best Regards,
   Elie Al-Tawil, Sr. Mech Engineer
   Colorado, USA.

   Cheers,

"Satria, Utama" <satria.utama@se1.bp.com> wrote:

           Dear Fellows ;

Any idea what Int'l Code or Regulation that covers requirement of double locking closure for vessel or pig traps, such GD Engineering Bandlock 2 design ?

They preferably applicable Internationaly such API, ISO, OSHA, etc. But UKOOA,BS, EN, NORSOK also considerable.

Appreciate if you can return to me a.s.a.p.

Best Regards,

Satria Utama Relianto
Mechanical Engineer
Integrity Management
Engineering Support
BP Indonesia Business Unit
< email : satriau@bp.com > Telp. + 62 ( 21 ) 78548451
Fax. + 62 ( 21 ) 78549062

[Non-text portions of this message have been removed]



Any questions? Get answers on any topic at Yahoo! Answers. Try it now.