Re: Equipment foundation

From: <ranjeet.borude@tripatra.com>
Date: Mon Dec 04 2006 - 21:47:00 EST


My thinking is bit different,

We should consider operability also. Most of the time small vessels have operating valves attached to nozzles, we may make these valves difficult to operate. Nozzle should be easy to approach from walkway. Instrument nozzles (Pressure Indicator, Level Gauges) should be placed so that operator can read it easily from walkway.

Regards,

Ranjeet

"umesh k.n." <umesh_kn@yahoo.com>
Sent by: <a href="/group/PipingDesign/post?postID=1eztSU90k2B2341lX2GXaHPIDD9cLDAdv0BUUG9ZjhvzHLozkGMQRx31UqH7pFobkiDNr9GDHCwqhPDIe6EdLA_Y5Q4z-g">PipingDesign@yahoogroups.com</a> 05/12/2006 04:49
Please respond to PipingDesign

         To:     <a href="/group/PipingDesign/post?postID=1eztSU90k2B2341lX2GXaHPIDD9cLDAdv0BUUG9ZjhvzHLozkGMQRx31UqH7pFobkiDNr9GDHCwqhPDIe6EdLA_Y5Q4z-g">PipingDesign@yahoogroups.com</a>
         cc:
         Subject:        Re: [PipingDesign] Equipment foundation


Vijay K. Chavhan said,
"there is one rule which follows every nozzle orientation that what ever
piping is done must be travel minimum distance"

YES most of the times & NO Some times.
When a minor equipment/pump located close to major equipment, and if the fluid temperature is relatively high, "Nozzle will be located away (little bit), i.e. not exactly towards the equipment" Reason: By doing so, piping layout generally comprises of 2 or more elbows which makes the layout flexible.

Rgs,
Umesh Ken.,Senior Piping Specification Engineer, Alcan Engineering Pty. Ltd., Brisbane, QLD, Australia

Favorite saying:
"Our lives begin to end the day we become silent about things that
matter"? ........... Dr. Martin Luther King, Jr

Dear bharathkumar

Your first ans, is Yes, there is one rule which follows every nozzle orientation that what ever piping is done must be travel minimum distance and with supporting facility so nozzle must be kept in htat direction. generally the nozzle piping attachment nozzle kept in piperack direction. then manhole wich is kept towrds walkway direction.

generally octagonal foundation is placed on the equipment where there is not more no of nozzle at top.

and Piba is the best sofware which i suggest best to calculating mto.

regards'
Vijay K. Chavhan
Piping engineer.
Uhde india ltd, vikroli.
mumbai.

Send instant messages to your online friends http://au.messenger .yahoo.com

[Non-text portions of this message have been removed]



Want to start your own business?
Learn how on Yahoo! Small Business.
<a href="http://smallbusiness.yahoo.com/r-index">http://smallbusiness.yahoo.com/r-index</a>

[Non-text portions of this message have been removed]

[Non-text portions of this message have been removed] Received on Mon Dec 04 21:47:00 2006

This archive was generated by hypermail 2.1.8 : Tue Mar 04 2008 - 11:40:38 EST