Re: Equivalent of amount of Energy stored in vessels in term of TNT

From: <Christopher>
Date: Sun Jan 21 2007 - 15:53:00 EST


On Jan 21, 2007, at 9:21 AM, elie altawil wrote:

> Read first section:
> <a href="http://www.llnl.gov/es_and_h/hsm/doc_18.02/sup32-03-appb.pdf">http://www.llnl.gov/es_and_h/hsm/doc_18.02/sup32-03-appb.pdf</a>
The analysis is also noteworthy for what ws left out, namely a calculation for the integral flange on the end of the vessel. The clamp ring is also subjected to bending like a slip-on flange and that wasn't addressed either.
>

Christopher Wright P.E. |"They couldn't hit an elephant at <a href="/group/PipingDesign/post?postID=AdquvWr0VdPM6nLzkG93Gl_ArwwNp5TIgRN5MPC7bTHKr3Iupw-iyxuBtsCnQ5AcnmWfC8jQznF_">chrisw@skypoint.com</a> | this distance" (last words of Gen.

.......................................| John Sedgwick, Spotsylvania