It is all spelled out for you in API 520. I believe the crieteria for
inlet/outlet piping is:
Also download and read the following article: <a href="http://www.fauske.com/Download/Chemical/ProcessSafety/FAInews_Vol9_No1.pdf">http://www.fauske.com/Download/Chemical/ProcessSafety/FAInews_Vol9_No1.pdf</a>
Regards,
sen_petro <sen_petro@yahoo.co.in> wrote:
HELLO SIRS,
iAM WORKING AS A PROCESS ENGINEER IN KAVIN ENGINEERING , INDIA I HAVE
SOME DOUBTS IN SIZING INLET AND OUT LET LINES FOR A PSV ROUTED TO HP
FLARE . EVEN THOUGH I CONSIDER PRESSURE DROP , VELOCITY(MACH) . IS THER
ANY OTHER CRITERIA TO FOLLOW . PLS HELP ME IN THIS IAM WORKING FOR FPSO
DESIGN
REGARDS
SENTIL KUMAR M
PROCESS ENGINEER
KAVIN ENGINEERING
TAMIL NADU
INDIA
+919942747779
[Non-text portions of this message have been removed] Received on Mon Feb 12 20:46:00 2007