Mr Imran,
visit "http://www.engdyn.com/pulsation/pipingfld.htm" which provides some published papers on the subject.
regards,
D.K.M.Rao.
"Farhad" <farhad_ss@yahoo.com>
Sent by: <a href="/group/PipingDesign/post?postID=st3zW4VW3vrEIKWqIHvb5KUdzyCId6G-9c7lY7EfCitJJZU1X6w5wCNfC-sow-QMpnun7OQKzjj70qe8uws_IXD8nQ">PipingDesign@yahoogroups.com</a>
02/12/2007 03:15 PM
Please respond to
<a href="/group/PipingDesign/post?postID=st3zW4VW3vrEIKWqIHvb5KUdzyCId6G-9c7lY7EfCitJJZU1X6w5wCNfC-sow-QMpnun7OQKzjj70qe8uws_IXD8nQ">PipingDesign@yahoogroups.com</a>
To
<a href="/group/PipingDesign/post?postID=st3zW4VW3vrEIKWqIHvb5KUdzyCId6G-9c7lY7EfCitJJZU1X6w5wCNfC-sow-QMpnun7OQKzjj70qe8uws_IXD8nQ">PipingDesign@yahoogroups.com</a>
cc
Subject
[PipingDesign] Vibration
Dear Imran,
Definitely, you should use CAESAR II software to solve this problem. There are a few steps as follows:
1- Collect field data (displacements, RPM of pumps, pipe support configuration, etc.)
2- Model piping system in CAESAR II. 3- Run static analysis. 4- perform Harmonic analysis and enter harmonic displacement at pump-pipe node.
I hope it helps you.
Regards,
Farhad
--------------------------------------------------------------------------------\ ------------------
Confidentiality Notice : This e-mail and any attachments are confidential to the addressee and may also be privileged. If you are not the addressee of this e-mail, you may not copy, forward, disclose or otherwise use it in any way whatsoever. If you have received this e-mail by mistake, please e-mail the sender by replying to this message, and delete the original and any print out thereof.
[Non-text portions of this message have been removed] Received on Thu Feb 15 06:24:00 2007
This archive was generated by hypermail 2.1.8 : Tue Mar 04 2008 - 11:40:49 EST