energy requirement

From: <praveen>
Date: Thu Feb 22 2007 - 03:49:00 EST


Mr. Rao,

   please check my calculation and correct me if you find any scope:

   Question: to raise the temperature of 350 liters water from 15 degree centigrate to 80degrere at atmospheric pressure my compney used two electric immersion water heater of 3 kw and claiming that it will heat the water to desire temperature with in one hour, i think they are wrong. my calculation is as under:

   350 liters = .350 meter cube

   weight of water = .350 x 1000 = 350kg

   heat require = mst= 350x1x65=22750 jule

   heaters are giving 6000 jule per second

   heaters are of less capacity. kindly suggest the correct specification. because I am thinking that at least two number of heater of 11Kw should be used.

Dacharaju Krishnamohan Rao <dk_rao@qp.com.qa> wrote:

           Mr Imran,

visit "http://www.engdyn.com/pulsation/pipingfld.htm" which provides some published papers on the subject.

regards,
D.K.M.Rao.

"Farhad" <farhad_ss@yahoo.com> Sent by: <a href="/group/PipingDesign/post?postID=36Uy4aQZSJ4euJn_cmcqmmSAG8ENzboBpNqCB73Uw2HMT7wrQTVVZpp3IongUYOLC9ksHykkKQ3r2MyLsVCIWbnG4Cg">PipingDesign@yahoogroups.com</a> 02/12/2007 03:15 PM
Please respond to
<a href="/group/PipingDesign/post?postID=36Uy4aQZSJ4euJn_cmcqmmSAG8ENzboBpNqCB73Uw2HMT7wrQTVVZpp3IongUYOLC9ksHykkKQ3r2MyLsVCIWbnG4Cg">PipingDesign@yahoogroups.com</a>

To
<a href="/group/PipingDesign/post?postID=36Uy4aQZSJ4euJn_cmcqmmSAG8ENzboBpNqCB73Uw2HMT7wrQTVVZpp3IongUYOLC9ksHykkKQ3r2MyLsVCIWbnG4Cg">PipingDesign@yahoogroups.com</a> cc

Subject
[PipingDesign] Vibration

Dear Imran,

Definitely, you should use CAESAR II software to solve this problem. There are a few steps as follows:

1- Collect field data (displacements, RPM of pumps, pipe support configuration, etc.)

2- Model piping system in CAESAR II.
3- Run static analysis.
4- perform Harmonic analysis and enter harmonic displacement at pump-
pipe node.
5- Tweak some dynamic parameters to model exact problem. 6- Add some stiffness (pipe support) to your piping system, wherever possible.
7- Run static then dynamic analysis to see changes.

I hope it helps you.

Regards,
Farhad

Confidentiality Notice : This e-mail and any attachments are confidential to the addressee and may also be privileged. If you are not the addressee of this e-mail, you may not copy, forward, disclose or otherwise use it in any way whatsoever. If you have received this e-mail by mistake, please e-mail the sender by replying to this message, and delete the original and any print out thereof.

[Non-text portions of this message have been removed]



  Here’s a new way to find what you're looking for - Yahoo! Answers

[Non-text portions of this message have been removed] Received on Thu Feb 22 03:49:00 2007