On Feb 22, 2007, at 2:49 AM, praveen purohit wrote:
> please check my calculation and correct me if you find any scope:
I make the heat requirement to be 26.4 kw. The specific heat of water is 4200 j/kg-C. You're using a specific heat of 1 which isn't right.
Just so you'll know, you should always, always, always carry through a units check when you do a calculation like that.
Christopher Wright P.E. |"They couldn't hit an elephant at <a href="/group/PipingDesign/post?postID=T7x2Z1K6YzHcdGnkoUai47ERH3auKpv55VG24FHtwhj_1IAZx9gaTJNqJLCQCnqFn8d4Zr4w-aqY">chrisw@skypoint.com</a> | this distance" (last words of Gen.
.......................................| John Sedgwick, Spotsylvania1864)