If the branch connection is at 90 deg or perpendicular to the pipe, (2-sin beta)
is 1.
If the branch connection is at an angle of <90 deg, the cutout area (or coupon) will be oval shape which is larger than the flow area of the branch pipe by (2 - sin beta).
A 45 deg branch connection the coupon will be (2-sin pi/4) = 29.3% larger than a coupon from a 90 deg branch.
Cheers,
Elie Al-Tawil, Sr. Mechanical Engineer Denver, Colorado
Sarawot / MPS <p_sarawut@mitrproject.co.th> wrote:
Dear All,
Please explain me about Branch connection calculation in B31.3 why A1 multiply
by (2-sin?)?
Best regards,
Hezb Sky
[Non-text portions of this message have been removed]
[Non-text portions of this message have been removed]
Received on Tue Feb 27 20:02:00 2007
This archive was generated by hypermail 2.1.8 : Tue Mar 04 2008 - 11:40:49 EST