Re: Branch connection

From: <elie>
Date: Tue Feb 27 2007 - 20:02:00 EST


If the branch connection is at 90 deg or perpendicular to the pipe, (2-sin beta) is 1.

   If the branch connection is at an angle of <90 deg, the cutout area (or coupon) will be oval shape which is larger than the flow area of the branch pipe by (2 - sin beta).

   A 45 deg branch connection the coupon will be (2-sin pi/4) = 29.3% larger than a coupon from a 90 deg branch.

   Cheers,

   Elie Al-Tawil, Sr. Mechanical Engineer    Denver, Colorado

Sarawot / MPS <p_sarawut@mitrproject.co.th> wrote:

           Dear All,
Please explain me about Branch connection calculation in B31.3 why A1 multiply by (2-sin?)?

Best regards,

Hezb Sky