How to you protect SS from chloride attack if used, without coating,
for Seawater?
A J
Lead Design Engineer
From: <a href="/group/PipingDesign/post?postID=JQR4drbQVveQMFcOY6TzQz93b53zGZkm2l_BWarkSQCkWjyzVetPIvEuixO7prGSZxYx6fHom4ES789R1T3-3Aw42nTavIA">PipingDesign@yahoogroups.com</a> [mailto:<a href="/group/PipingDesign/post?postID=JQR4drbQVveQMFcOY6TzQz93b53zGZkm2l_BWarkSQCkWjyzVetPIvEuixO7prGSZxYx6fHom4ES789R1T3-3Aw42nTavIA">PipingDesign@yahoogroups.com</a>]
On Behalf Of Dacharaju Krishnamohan Rao
Sent: 05 April 2007 07:19
To: <a href="/group/PipingDesign/post?postID=JQR4drbQVveQMFcOY6TzQz93b53zGZkm2l_BWarkSQCkWjyzVetPIvEuixO7prGSZxYx6fHom4ES789R1T3-3Aw42nTavIA">PipingDesign@yahoogroups.com</a>
Subject: Re: [PipingDesign] Re: Seawater cooling for power plant
Use of SS316L and GRP for seawater service is also in practice.
There is also an improvement of applying a Specail (paint) Coating
inside
on SS316L for an extended life where seawater flow disturbances occur
such
as downstream of valves.
regards,
D.K.M.Rao.
Alok Dubey <<a href="/group/PipingDesign/post?postID=9GAK0IAWg5ymkdIbxfD5w16D2DIklIDwpq42dK39g0swHnxbWygkMJbz9No9RchFRYLBWxhLrl-Yx0Cpvd87Rg">terrion_786@yahoo.co.in</a> <mailto:terrion_786%40yahoo.co.in> >
Sent by: <a href="/group/PipingDesign/post?postID=JQR4drbQVveQMFcOY6TzQz93b53zGZkm2l_BWarkSQCkWjyzVetPIvEuixO7prGSZxYx6fHom4ES789R1T3-3Aw42nTavIA">PipingDesign@yahoogroups.com</a>
<mailto:PipingDesign%40yahoogroups.com>
04/04/2007 08:10 PM
Please respond to
<a href="/group/PipingDesign/post?postID=JQR4drbQVveQMFcOY6TzQz93b53zGZkm2l_BWarkSQCkWjyzVetPIvEuixO7prGSZxYx6fHom4ES789R1T3-3Aw42nTavIA">PipingDesign@yahoogroups.com</a> <mailto:PipingDesign%40yahoogroups.com>
To
<a href="/group/PipingDesign/post?postID=JQR4drbQVveQMFcOY6TzQz93b53zGZkm2l_BWarkSQCkWjyzVetPIvEuixO7prGSZxYx6fHom4ES789R1T3-3Aw42nTavIA">PipingDesign@yahoogroups.com</a> <mailto:PipingDesign%40yahoogroups.com>
cc
Subject
Re: [PipingDesign] Re: Seawater cooling for power plant
Hi JUn,
stainless could be duplex (22 Cr%,...) or super duplex (25%) and that
was
the intent. These two grades are used extensively in subsea or marine
enviornment.
Cheers!
Sent: Tuesday, April 3, 2007 1:52:53 PM
Subject: [PipingDesign] Re: Seawater cooling for power plant
Stainless steel pipe material for sea water service?? Not in our plant.
Cupro-nickel material may be OK for US Navy application but in process/power plants where the coolant header (sea water service) is about 108 " NPS size - well you might have to rethink the economics of utilizing such material.
[Non-text portions of this message have been removed]
Confidentiality Notice : This e-mail and any attachments are confidential to the addressee and may also be privileged. If you are not the addressee of this e-mail, you may not copy, forward, disclose or
otherwise use it in any way whatsoever. If you have received this e-mail
by mistake, please e-mail the sender by replying to this message, and delete the original and any print out thereof.
[Non-text portions of this message have been removed]
[Non-text portions of this message have been removed] Received on Thu Apr 05 00:22:00 2007
This archive was generated by hypermail 2.1.8 : Tue Mar 04 2008 - 11:40:50 EST