Re: Vapor should be in Shell side or tube side....

From: <elie>
Date: Sat Jul 21 2007 - 11:28:00 EDT


Do not do it.

   Use a seamless elbow or replace a 5-D piece of the pipe and put the seam where you should. You also could cut a 5-D of the pipe, rotate 30 deg. and re-weld the same pipe.

   next time: provide pipe size, materials, grade, wt, process/service, pressure, temp, etc.

   Cheers,

ramar karuppaiah <ramarkaruppaiah@yahoo.co.in> wrote:

           Hallo gais,

I have problem during field erection, any body can help me.

The problem is the 90 degree elbow seam welding and the long seam welding of the pipe is coming in the same line. is their any problem if i can welding. It is the critical joints, Tie in joints.

With REGARDS

> Dear Friends,
> Please send me the list of Errors in ISO extraction
> in PDS.
>
> Thanks
>
> Dileep
>
>
> [Non-text portions of this message have been
> removed]
>
>

Once upon a time there was 1 GB storage in your inbox. To know the happy ending go to <a href="http://help.yahoo.com/l/in/yahoo/mail/yahoomail/tools/tools-08.html">http://help.yahoo.com/l/in/yahoo/mail/yahoomail/tools/tools-08.html</a>



Be a better Globetrotter. Get better travel answers from someone who knows. Yahoo! Answers - Check it out.

[Non-text portions of this message have been removed] Received on Sat Jul 21 11:28:00 2007