Re: regarding wall thick calculation

From: <ravi.kant@fluor.com>
Date: Mon Jul 23 2007 - 00:00:00 EDT

For Pipe wall thickness calculation,
we start calculation with the operating pressure...

which is then multiplied by the factor to get Design Pressure. i.e.

   Operating Pressure x 1.5 = Design Pressure.

and then, This Design Pressure is used as the ' P ' in the formula for the Wall thickness Calculation.

Regards,

Ravi

"Dhayanithi V" <pipingworld@gmail.com>
Sent by: PipingDesign@yahoogroups.com
07/22/2007 04:17 PM
Please respond to PipingDesign

To
PipingDesign@yahoogroups.com
cc

Subject
[PipingDesign] regarding wall thick calculation

for pipe wall thickness calculation, which pressure we have to take into account like *operating*, *design*,*test* pressure

[Non-text portions of this message have been removed]



The information transmitted is intended only for the person or entity to which it is addressed and may contain proprietary, business-confidential and/or privileged material. If you are not the intended recipient of this message you are hereby notified that any use, review, retransmission, dissemination, distribution, reproduction or any action taken in reliance upon this message is prohibited. If you received this in error, please contact the sender and delete the material from any computer.

Any views expressed in this message are those of the individual sender and may not necessarily reflect the views of the company.


[Non-text portions of this message have been removed]
Received on Mon Jul 23 00:00:00 2007