Re: Piping stress analysis of Vertical reboiler

From: <Christopher>
Date: Sat Aug 25 2007 - 12:35:00 EDT

On Aug 25, 2007, at 12:52 AM, kiransinh wrote:

> Yes, Hitesh is right. If system is not safe in static condition
> then useless to check with wind and seismic analysis.
Not to the point. That spring might make it 'safe' (bad choice of words, BTW) under static loading, but render it unable to resist seismic and wind loading. Carrying determinate lateral loading into a constant force spring might very well bottom it out and break something

Christopher Wright P.E. |"They couldn't hit an elephant at chrisw@skypoint.com | this distance" (last words of Gen.

.......................................| John Sedgwick, Spotsylvania
1864)
http://www.skypoint.com/~chrisw/ Received on Sat Aug 25 12:35:00 2007