On Sep 26, 2007, at 12:14 PM, Ken Nisly-Nagele wrote:
> In the Power Piping Code, B31.1 para. 101.7.2 does not direct the
> design of
> metallic bellows expansion joints to be in accordance with an Appendix
> or
> any industry standard, and so it does not specifically address fatigue
> design of the bellows elements.
Section VIII has rules for expansion joints based on the EJMA rules.
I'm sure you can use those provisions with B31.1.
Christopher Wright P.E. |"They couldn't hit an elephant at <a href="/group/PipingDesign/post?postID=1X0Q6EGxzn_PNR5n_sxkUU9MDJalV3hdaNNP_GhnYrpP4KSoaq8kW5GNY2WTTADwBDNpHcZYSPQtEA">chrisw@skypoint.com</a> | this distance" (last words of Gen.
____________________| John Sedgwick, Spotsylvania 1864)<a href="http://www.skypoint.com/~chrisw">http://www.skypoint.com/~chrisw</a> Received on Thu Sep 27 22:57:00 2007
This archive was generated by hypermail 2.1.8 : Tue Mar 04 2008 - 11:40:52 EST