A general definition of the trim is the 'wetted internal parts' of the
valve. The trunnion and stem are both wetted by the fluid in a ball valve.
The trim material selected is normally better in corrosion / erosion
resistance. The other consideration for stem and trunnion is the material
strength.
Sajit Viswan
AUH A353 NBAD 22 FL,
611 6351
ADA07730 / AE001WD1795