Re: mill tolerance for pipes by ASME B 31.8/ B31.4

From: <Hafiz>
Date: Wed Dec 05 2007 - 10:13:00 EST


Hello.

As far as mill tolerance is concern it is specified in ASTM material standard. As u mention mill tolerance of 12.5% ( it is not for ASME B31.3) is for ASTM A53 or ASTM A106 as specified in para 12.3 of ASTM A53 for ASTM A53 pipe and para 16.3 of ASTM A106 for ASTM A106 pipe. SImilarly for ASTM 312 you can find mill tolerance in table 3. therefore based on the refrences u can say its not mandatory reuirment of ASME B31.3 but its requirment of ASTM Material to be used for piping. Similarly if you are gona use A106 or A312 in B31.4 or B31.8 u have to follow the mill tolerance mention in the ASMT standard. also mill tolerance is mandatory requirment of B31.3 but not 12.5% is the requirment.ay be Vary from material to material.

Regards



Hafiz Ali Alvi
PIPING DEPARTMENT
E-MAIL <a href="/group/PipingDesign/post?postID=3vnHzeBKqDIuMCAcaUUNn0Uejv-kZrEzGRDBT6NVmxruoSqOJUXiUCiJCNO1Dwv4f6PrnaDrDHci4KBp2LWm">halvi@jgc-descon.com.pk</a> PHONE # 042-5812263 (Ext 247)


CONFIDENTIALITY NOTICE
This email and any files transmitted with it are confidential and intended solely for the use of the individual or entity to whom they are addressed. If you have received this email in error please delete the email and any attachment(s) and notify the sender. This footnote also confirms that this email message has been scanned for the presence of computer viruses.

dd jdh <saduemk@yahoo.co.in> Sent by: <a href="/group/PipingDesign/post?postID=ARVnllLzEJ08CrQhYMPFkkMETrOcgMR6pP51W-wvkDEcw4nZxyTX8sdXboTlbED59GjC4NT8WrYUNfv4c4EtN-9Ek-pAjA">PipingDesign@yahoogroups.com</a> 12/05/2007 04:39 PM
Please respond to PipingDesign

         To:     pipe <pipingdesign@yahoogroups.com>
         cc:
         Subject:        [PipingDesign] mill tolerance for pipes by ASME B
31.8/ B31.4

Hi every one,

The ASME Code B 31.3 has mentioned specifically on the addition of mill tolerance of 12.5% in its pipe wall thickness. But is this mill tolerance mandatory for wall thickness of process pipes following B31.4 and B31.8 Codes.

Thanks&Regards

sadanand
middle east