Re: Seawater cooling for power plant

From: <delacruzjuan1977>
Date: Sat Feb 02 2008 - 05:55:00 EST


The failure is not due to flow disturbance if an SS pipe is used for sea wtaer service. The concern is SCC. And the moment it starts, failure is sure to happen - its just a matter of time. There are other pipe material that is suitable for use for sea water application . One is a cement lined CS pipe (coated and wrapped for U/G application) or fiberglass pipe - both have a pretty good service life.

Received on Sat Feb 02 05:55:00 2008