Gentlemen
Generally, after Hydrotesting a pipe spool, we do
Golden Welds.
Do we have something similar to this in hydrotesting
of PVC pipes? What would be best way to test the PVC
joints which cannot be hydrotested?
Please comment on this.
Regards
Amjad
> Amjad - Normally a reference to threaded connections
> for instrumentation
> in a piping spec is in reference to pressure sensing
> instruments (
> including flow instruments) - which ape provided
> with male npt
> connections. The piping system will include a "root
> valve" which will have
> a connection per piping spec ( socket welded for
> example) on one side & a
> female threaded connection on the other side where
> direct mounting of a
> threaded instrument or the installation of a
> threaded tubing adaptor which
> will connect to a remote mounted instrument is
> possible. Take a look at
> your instrumentation department's standard
> installation details - normally
> a reference is made to differentiate between the
> piping & instrumentation
> disciplines -
> Is this your case?
> Bruce R. Raymond
> Senior Design Supervisor
> Fluor
>
________________________________________________________________________________\