A J:
Assuming that your procedure is written by a knowledgeable person, or team, then there must be a reason. Perhaps there is a measurement that is required to verify some condition that will not provide a proper response if there is the added current on the pipe. Perhaps there is even a desire to measure the potential between the pipe and ground without the ICCP to get a baseline at the time of commissioning, that might aid in future checks of a preventive or predictive maintenance (PM) program. Commissioning should not require a very long time, so there should be no damage to the line from having the ICCP off for a few days. Even if there is, then your service is a very challenging one anyway, and a good PM program is paramount.
... Bruce D. Bullough ...
Lead Process Engineer
Foth Production Systems, LLC
8550 Hudson Boulevard North, Suite 100
Lake Elmo, MN 55042
Direct: +651-288-8598 Fax: +651-288-8551
http://www.foth.com
IMPORTANT NOTICE
This communication including any attachments, (E-mail) is confidential and
may be proprietary, privileged or otherwise protected from disclosure. If
you are not the intended recipient, please notify the sender, permanently
delete this E-mail from your system and destroy any copies. Any use of
the E-mail, including disclosure, distribution or replication, by someone
other than its intended recipient is prohibited.
This E-mail has the potential to have been altered or corrupted due to transmission or conversion. It may not be appropriate to rely upon this E-mail in the same manner as hard copy materials bearing the author's original signature or seal.
"Arif Javed" <ajaved@qchem.com.qa>
Sent by: PipingDesign@yahoogroups.com
02/11/2008 11:36 PM
Please respond to
PipingDesign@yahoogroups.com
To
PipingDesign@yahoogroups.com
cc
Subject
[PipingDesign] ICCP of the Hydrocarbon Line
Gents we are about to commission C4+ (hydrocarbon) pipeline. This line is protected by ICCP. The commissioning procedure says that we have to either switch off or disconnect ICCP (impressed current cathodic protection) before commissioning. After the line is commissioned we again switch on the ICCP system.
Different people have different views on this. Some say that it is mandatory and some say they never heard of this and it is not required at all. What the group says about this?
Regards
A J
Lead Design Engineer
DES/Technical Dept
........best is NOT good enough! (aj) Received on Tue Feb 12 08:53:00 2008