If you have ever used Algor Pipeplus or Coade Caesar II then you'll be familiar with its equipment component report. Consider the case of pump flange loading meeting the API Standard 610. First thing that you'll notice is that it is limited to 4 inch disch size. Noticed also the equations. Permitted loads appears to be based only on pump weights and flange size. Question is Why? For one thing, piping arrangement to pump disch/suction has to wait till the pumps has been selected and drawings showing nozzle detail provided by the manufacturer. It makes makes more sense it the flange load be based on the duty of the pump or better still standardized the pump flange nozzle and do away with the flexibililty analysis.
Ditto to API 617 and NEMA SM-23 for compressor and turbines respectively. Difference being that allowable piping loads are based on equivalent diameter. Received on Thu Jul 26 19:19:00 2001
This archive was generated by hypermail 2.1.8 : Tue Mar 09 2010 - 00:20:21 EST