Why does any one thread 3" pipe?
We can weld two joints in the time it takes to thread one, and their is
no where near the restriction in a welded line not to mention the fact
that they are no pockets in the fittings for water to collect in.
But I could be a bit biased.
Remember to oversize for future expansion, and an air header can never
be too large the cost difference between 3" and 4" is slight. look in to
it. grade the piping as much as you can and use plenty of drip legs, and
drain traps. If you need high quality air look in to a refrigerated
drier.
On Monday, September 24, 2001, at 10:08 AM, ljh@kochllc.com wrote:
> Hi, folks
>
> I have a quick and easy question. We are planning a small retrofit
> of a compressed air blow-down system and the customer would like to
> use screwed (NPT) pipe for a distribution line. If he uses 3"NPT for
> the distribution loop, would he be in compliance with ASME?
>
> Thanx
>
>
>
<Attachment missing>
>
>
> ___________________________________________________
> If you want only site update notifications, go here:
> mailto:PipingDesignNews-subscribe@yahoogroups.com
> _____________________
> Piping Design Central
> [ http://www.PipingDesign.com ]
> ________________________________________
> We hope you find this newsletter useful.
> If not, you can unsubscribe at:
> PipingDesign-unsubscribe@yahoogroups.com
> Post message: PipingDesign@yahoogroups.com
> Subscribe:Â PipingDesign-subscribe@yahoogroups.com
>
> Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service.
"It is foolish and wrong to mourn these men who died. Rather, we
should thank God that such men lived."
General George Patton
[Non-text portions of this message have been removed] Received on Tue Sep 25 01:12:00 2001
This archive was generated by hypermail 2.1.8 : Mon Oct 27 2008 - 20:23:54 EDT