The seismic force is occasional, whereas the vibration could be due to the two phase flow of the medium inside the pipe or other reasons and will always be there during operation. In my opinion, the cause of vibration must be attended to first. If unaviodable, we can use the vibration snubber.
thanks
-----Original Message-----
From: mechengr1977 [mailto:mechengr1977@yahoo.com]
Sent: Friday, November 15, 2002 9:16 AM
To: PipingDesign@yahoogroups.com
Subject: [PipingDesign] Re: Mechanical or hydraulic snubber
you may be spending some big money for nothing. I will not recommend using a mechanical or hydraulic snubbers to control piping vibration (a lot has this reaction). but i will use snubbers (even knowing i would face a problem just maintaining this big sucker)when warranted to control the movement of pipe in the event of a seismic event. are there any difference between vibration and seiesmic event - sure there is.
Discussion List sponsor: Texas Flange - a good source for information on
industrial flanges, all they ask is for referrals for designs they help
with.
877-610-8924.
www.texasflange.com
Your use of Yahoo! Groups is subject to the Yahoo! Terms of <http://docs.yahoo.com/info/terms/> Service. Received on Thu Nov 14 23:38:00 2002