Shivakumar,
There are several ways to reduce moment Mx on pump nozzle depending on the
piping layout.
I tried to assume a piping layout for a pump with header perpendicular to pump
suction pipe(for end suction pump) with different elevation.In that case, if
you reduce the displacement in z direction for header ,you can reduce Mx on pump
nozzle.
If you send your piping layout sketch by e mail , I can further study the case.
Arif Patel
Dear friends,
I'm doing analysis for piping where pump is getting connected at one end. I have fixed the pump nozzle as fixed point. Since there was a huge value for moment 'Mx', I have introduced one Ry, rotational restraint. Now all the moment has been transferred to this restraint. It is not possible to design the support for such a huge moment. Please advise any other method to reduce these moments.
Thanks
shivakumar