Re: pump nozzle loads

From: <Arif>
Date: Tue Nov 19 2002 - 12:38:00 EST

Shivakumar,

There are several ways to reduce moment Mx on pump nozzle depending on the piping layout.
I tried to assume a piping layout for a pump with header perpendicular to pump suction pipe(for end suction pump) with different elevation.In that case, if you reduce the displacement in z direction for header ,you can reduce Mx on pump nozzle.

If you send your piping layout sketch by e mail , I can further study the case.

Arif Patel

   Dear friends,

   I'm doing analysis for piping where pump is getting    connected at one end. I have fixed the pump nozzle as    fixed point. Since there was a huge value for moment    'Mx', I have introduced one Ry, rotational restraint.    Now all the moment has been transferred to this    restraint. It is not possible to design the support    for such a huge moment. Please advise any other method    to reduce these moments.

   Thanks

   shivakumar



   Do you Yahoo!?
   Yahoo! Web Hosting - Let the expert host your site    http://webhosting.yahoo.com

   Discussion List sponsor: Texas Flange - a good source for information on industrial flanges, all they ask is for referrals for designs they help with.

   877-610-8924.
   www.texasflange.com



   unsubscribe: PipingDesign-unsubscribe@yahoogroups.com

   Somebody email this guy: RAMESH@ALPHADXB.COM

   Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service.