Steam Turbine Inlet Piping (Adobe PDF)
<<The steam turbine along with other two turbines of similar design was
mounted on an elevated compressor
deck. As a rule, the inlet piping ran from below the turbine, and outlet
vice-versa. The working fluid of the
driven compressor was Synthesis Gas (N2+H2). While on the turbine side the
temperature & pressure
conditions were, 900 Deg F, and 1500 psi. Rotational speed of the turbine
was 6000 RPM above second
critical. Turbine had significant thermal growth on operating conditions.>>
The Piping Network
http://www.pipingdesign.com/pipingnetwork.html
Received on Mon Nov 25 01:51:00 2002
This archive was generated by hypermail 2.1.8 : Mon Oct 27 2008 - 20:23:58 EDT