Re: DIN Flange Detail Drawings

From: <Christopher>
Date: Sat Nov 23 2002 - 12:20:00 EST


>Are the European specs simply conversions to ASME?
No. I think the present standards are ISO anyway and not DIN. I thought your first post said you were looking for ANSI flanges. I tried doing this conversion once in a past life--it doesn't work, chiefly because DIN and ISO are set up to somewhat different design criteria and much of the loading corresponds to metric bolting: different bolt sizes and material mechanical properties make for different geometry.

What exactly are you looking to do?

Christopher Wright P.E. |"They couldn't hit an elephant at <a href="/group/PipingDesign/post?postID=evPvOytfqBPFVDmLO7QH9BYRVQoPuOBX9Owa7-eZBzWVbBH1PQ_3DSFFnnTlexbEWwjrJNW7kNocORKz9Zk">chrisw@skypoint.com</a> | this distance" (last words of Gen.

___________________________| John Sedgwick, Spotsylvania 1864)
<a href="http://www.skypoint.com/~chrisw">http://www.skypoint.com/~chrisw</a> Received on Sat Nov 23 12:20:00 2002