RE: Hot Tapping Plant Air and Instrument Air

From: <Steve>
Date: Tue Nov 26 2002 - 20:24:00 EST


I have been caught with this one a few times and there are two ways I have got round it:
Sometimes a branch line has a larger than necessary isolating valve. If this is the case then sometimes it is possible to make a new connection downstream is the branch valve. You do have to interrupt the branch flow for a short time, but the remainder of the air system can remain in service. Lock out the isolating valve to avoid an unpleasant surprise. If branch interruption is not permitted, a rental instrument air set can help out.

Sometimes a temporary jumper pipe can be installed across two existing valves, and the line in between isolated by two more isolating valves.

On occasion, with water, I have welded a socket to the outside of a live pipe, fitted a ball valve and then drilled through the pipe wall using a gland around the drill stem. This is dodgy at best, and would be even more dodgy on air as there is a higher risk of blowout and getting metal cuttings in the pipe.

Think of the exercise as two problems; one to create a dead pipe section and the other to stab in a valve.

Cheers

Steve McKenzie

-----Original Message-----
From: regoldst [mailto:regoldst@attbi.com] Sent: Wednesday, November 27, 2002 1:48 PM To: <a href="/group/PipingDesign/post?postID=Du6--YnVY9o22NFLx4vBI194jhxAxQSf2Tk3kEY_gxVXJ5bJoECYQQ9X_ZxUGIIYPXC9w54AWmsXMUtF_TBa-miggQ">PipingDesign@yahoogroups.com</a> Subject: [PipingDesign] Hot Tapping Plant Air and Instrument Air

I'm presently working in a Major Oil Refinery in the United States and I was told that you can't Hot Tap air lines due to the generaed heat problems and the Refinery won't allow clamp-on tees for Tapping, so I'm at a loss for ideas. Shutting down plant air and instrument air is out of the question and spare valved connections have been used, so I'm looking for ideas. I don't remember this being a problem in the past. Has there been a recent code change or have I been doing this wrong for the last decade or so?

Discussion List sponsor: Texas Flange - a good source for information on industrial flanges, all they ask is for referrals for designs they help with.
877-610-8924.
www.texasflange.com



unsubscribe: <a href="/group/PipingDesign/post?postID=4cCISjLfVFYN9zxGID8OAbSRUXJfjce0inPg3LYNXfIqHS4ihOHTgc4m1ngTo9n9xVbx4600zfXKDijcvnopXjzXCLYr7tD-4kP74R6U">PipingDesign-unsubscribe@yahoogroups.com</a>

Your use of Yahoo! Groups is subject to <a href="http://docs.yahoo.com/info/terms/">http://docs.yahoo.com/info/terms/</a> Received on Tue Nov 26 20:24:00 2002

This archive was generated by hypermail 2.1.8 : Tue Mar 04 2008 - 11:40:26 EST