Pravin/Tanmoy,

You don't need calculus, simple geometrical calculations will do !

Volume of a Torus is PI*D time the Area of C/S, in this case it is a Hollow Circular Torus, thus

Formula for volume of a Hollow Circular Torus is

[PI*D] * PI * (d1^2 - d2^2) / 4

OR

PI^2 * D * (d1^2 - d2^2) / 4

where D = Mean Bend Radius (@ centerline)

	 d1 = Outside Diameter (OD of Elbow/Pipe + Insulation thk.)
	 d2 = Inside Diameter  (OD of Elbow/Pipe)

Divide the value by 4 for 90° bends, by 8 for 45° bends & so on. . .

Cheers
Sharma, R
971.507.682.904

-----Original Message-----
From: Tanmoy Saha [mailto:Tanmoy.Saha@Halliburton.com] Sent: Wednesday, January 22, 2003 3:27 PM To: 'PipingDesign@yahoogroups.com'
Subject: RE: [PipingDesign] Insulation MTO

  Calculating the volume by integration (calculus).

Tanmoy Saha
Kellog Brown & Root, Singapore.
Ph. 6422 2535
Email. Tanmoy.Saha@Halliburton.com

-----Original Message-----
From: Patil, Pravin [mailto:Pravin.Patil@veco.com] Sent: January 22, 2003 7:37 PM
To: PipingDesign@yahoogroups.com
Subject: [PipingDesign] Insulation MTO

Dear Friends,
While calculating the insulation requirement of piping system, for pipes we calculate it by volume of hollow cylinder formula. Does anyboby know of any standards for calculation the volume of pipe fittings like 90 deg. elbows, 45 deg elbows etc.

Your views will be of great help.
Best Regards.

Discussion List sponsor: Texas Flange - a good source for information on industrial flanges, all they ask is for referrals for designs they help with.
877-610-8924.
www.texasflange.com



Discussion List sponsor: The fluid flow calculations website - www.LMNOeng.com - LMNO Engineering,
Research, and Software, Ltd.

unsubscribe: PipingDesign-unsubscribe@yahoogroups.com

Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/

Discussion List sponsor: Texas Flange - a good source for information on industrial flanges, all they ask is for referrals for designs they help with.
877-610-8924.
www.texasflange.com



Discussion List sponsor: The fluid flow calculations website - www.LMNOeng.com - LMNO Engineering,
Research, and Software, Ltd.

unsubscribe: PipingDesign-unsubscribe@yahoogroups.com

Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/ Received on Wed Jan 22 09:02:00 2003

This archive was generated by hypermail 2.1.8 : Mon Oct 27 2008 - 20:23:59 EDT