Thansk a lot, hankl46. Your reply is really what I request.
PS: N-480 was annulled on September 18, 2001, and the latest N-597-1 was approved on September 7, 2001.
Again, Thank you very much,
Samuel
-----Original Message-----
From: hankl46 [mailto:hleveret@aol.com]
Sent: Monday, June 02, 2003 3:50 PM
To: PipingDesign@yahoogroups.com
Subject: [PipingDesign] Re: Single-Phase Piping Internal E/C Control -
ASME Codecase N-480
Background:
Soon after a 1988 nuclear power plant feedwater piping component
failed due to flow assisted corrosion, the development of acceptance
criteria for locally thinned piping components was started. These
criteria were published in Electric Power Research Institute (EPRI)
Report NP-5911. This report later became the standard for the
evaluation of thinned piping components, which led to the development
of ASME Code Case N-480.
N-480 provides examination and analytical evaluation methods for pipe
wall thinning due to single-phase erosion and corrosion.
Yes, N-480 is now absolete. I think in 1999, N-480 has been superseded by Case N-597.
Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/
The information contained in this e-mail is intended only for the individual or
entity
to whom it is addressed. Its contents (including any attachments) are
confidential and
may contain privileged information. If you are not an intended recipient you
must not
use, disclose, disseminate, copy or print its contents. If you receive this
e-mail in
error, please notify the sender by reply e-mail and delete and destroy the
message.
[Non-text portions of this message have been removed] Received on Mon Jun 02 18:08:00 2003
This archive was generated by hypermail 2.1.8 : Tue Mar 09 2010 - 00:20:44 EST