RE: condensate line

From: <THOMAS>
Date: Wed Dec 24 2003 - 21:02:00 EST

Dear Lakshmi,

replacing with SSs304 or 316 is the usual action we take when we face this kind of issue. It has solved our problem after this replacement as Ss304/316 has much higher erosion resistance than CS materials.

>From: "Lakshmi V. Narayana" <LNarayana@safco.net>
>Reply-To: PipingDesign@yahoogroups.com
>To: "'PipingDesign@yahoogroups.com'" <PipingDesign@yahoogroups.com>
>Subject: [PipingDesign] condensate line
>Date: Wed, 24 Dec 2003 15:40:50 +0300
>
>
>Hello friends,
>
>We are facing a problem of erosion of elbows in Condensate line from
>reboiler to deaerator(two phase) . Present material is CS 106 GrB. Can we
>replace it with SS material to counter erosion problem. Can any share his
>experience on this.
>
>Lakshmi Narayana V
>
>========================================
>Discussion List sponsor: The fluid flow calculations website -
>www.LMNOeng.com - LMNO Engineering, Research, and Software, Ltd.
>=========================================
>To leave this list, send a blank email to:
>PipingDesign-unsubscribe@yahoogroups.com
>=========================================
>List home: http://groups.yahoo.com/group/PipingDesign/
>Main site: http://www.pipingdesign.com
>
>Yahoo! Groups Links
>
>To visit your group on the web, go to:
> http://groups.yahoo.com/group/PipingDesign/
>
>To unsubscribe from this group, send an email to:
> PipingDesign-unsubscribe@yahoogroups.com
>
>Your use of Yahoo! Groups is subject to:
> http://docs.yahoo.com/info/terms/
>
>



Keep track of Singapore & Malaysia stock prices. http://www.msn.com.sg/money/ Received on Wed Dec 24 21:02:00 2003