Yes, this is a poor description since there is an infinite number of planes that intersect the pump shaft. I suspect that it means when the piping is in the horizontal plane and connects with a pump a 90 degrees close to the pump suction flange, this is to be avoided.
Jacques
What does the following phrases mean. Suction piping is 1. In same plane as pump shaft. 2. Perpendicular to the pump shaft. Which is this plane? for a split casing multi stage centrifugal pump.
Sajit
Yahoo! Groups Sponsor
ADVERTISEMENT
------------------------------------------------------------------------------
Yahoo! Groups Links
a.. To visit your group on the web, go to:
http://groups.yahoo.com/group/PipingDesign/
b.. To unsubscribe from this group, send an email to:
PipingDesign-unsubscribe@yahoogroups.com
c.. Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service.
[Non-text portions of this message have been removed] Received on Sat Jan 03 07:43:00 2004
This archive was generated by hypermail 2.1.8 : Mon Oct 27 2008 - 20:24:02 EDT