And Carlos, I don't think that was a "stupid question", but the sort of thing the forum is here for........
... Bruce D. Bullough ...
Sebesta Blomberg & Associates
2381 Rosegate
Roseville, MN 55113 USA
651-634-7344 direct
651-634-7400 FAX
www.sebesta.com
-----Original Message-----
From: Steve McKenzie [mailto:mechproj@xtra.co.nz]
Sent: Monday, February 16, 2004 3:55 PM
To: PipingDesign@yahoogroups.com
Subject: RE: [PipingDesign] Allowable Loads on a Recip. Compressor
[bcc][faked-from][bayes]
Hi Carlos
API 618 may have what you are after.
Cheers
Steve
-----Original Message-----
From: ceacs [mailto:ceacs@yahoo.com.br]
Sent: Tuesday, February 17, 2004 10:17 AM
To: PipingDesign@yahoogroups.com
Subject: [PipingDesign] Allowable Loads on a Recip. Compressor
Hi,
Sorry to bother you guys with this stupid question, but i really need some help with this matter.
Are there any standard or calculation method available for Recip. Compressor nozzle allowable loads determination? (I believe API-617 only covers centrifugal and axil compressor)
Best Regards,
Carlos Eduardo
This archive was generated by hypermail 2.1.8 : Mon Oct 27 2008 - 20:24:02 EDT