Friends,
Piping exerts some loads on the equipment nozzles. The allowable nozzle
loads mentioned by any vessel or pump manufacturer are for design
conditions of the eqpts.
Sometimes the loads at design conditions are within allowable, but they may
exceed at the occasional load cases like wind or seismic.
As per B31.3, we can use 33% higher allowable stress for piping. But the API codes for pumps etc do not mention any such factor. Is there any thumb rule or factor for occasional cases to analyse eqpt nozzle loads?
If we send these loads to the manufacturer, they will just approve those without any modification in the nozzle design. This mean there must be some extra margin to cater for such cases. If anybody is aware, please enlighten me on this.
Best Regards.
Tushar Zope
Extn: 162
This communication and the information it contains:-
(a) Is intended for the person(s) or organisation(s) named above and for no
other person(s) or organisation(s).
(b) May be confidential, legally privileged and protected in law. Unauthorised
use, copying or disclosure of any of it may be unlawful. If you have received
this communication in error, please contact us immediately by email at
Postmaster@fwuk.fwc.com.
This archive was generated by hypermail 2.1.8 : Tue Mar 09 2010 - 00:20:53 EST