RE: Horizontal Dummy Leg Question

From: <Al>
Date: Fri Apr 16 2004 - 04:09:00 EDT

YES NOT UNCOMMON IN PIPELINE GROUND EXIT WHERE SHALLOW TURNS REQUIRED

-----Original Message-----
From: Paul Bowers [mailto:pbowers@pipingdesign.com] Sent: Thursday, April 15, 2004 5:50 PM
To: PipingDesign@yahoogroups.com
Subject: [PipingDesign] Horizontal Dummy Leg Question

Has anyone ever seen a horizontal dummy leg used on a 45 degree elbow?

Here's a quick sketch:

http://www.pipingdesign.com/drawings/dummy.jpg

It is assumed that the non-penetrating weld between the DL and the elbow would overlap, although the sketch doesn't show this.

Paul



PipingOffice - Excel Spreadsheets for Piping Calculations http://www.pipingoffice.us/

Main site: http://www.pipingdesign.com

Yahoo! Groups Links Received on Fri Apr 16 04:09:00 2004