Re: Leak Tests:
For gasket materials the ROTT ASTM helium test is used. (ROTT-Room Temperature Tightness.) New ASME (BFJ) flange leakage "rules" should be released sometime in the near future. Work we've done that relates this information to the piping flange problem can be found at www.paulin.com/prg/papers/liquidleak.pdf.
Regards,
Tony Paulin
> Is this good enough?
>
> http://www.ndt.net/article/ecndt98/offshore/268/268.htm
>
> Why would you want to test with He anyway.
>
> Paul
>
>
> ----- Original Message -----
> From: "e-Director" <segip@tm.net.my>
> To: <PipingDesign@yahoogroups.com>
> Sent: Tuesday, May 04, 2004 12:34 PM
> Subject: [PipingDesign] HELIUM LEAK TEST
>
>
> > Does anyone know how to conduct/method for helium leak test??
> >
> > Acceptable leak rate according to any Standard????
>
>
>
>
>
> =========================================
> PipingOffice - Excel Spreadsheets for Piping Calculations
> http://www.pipingoffice.us/
> =========================================
> Main site: http://www.pipingdesign.com
>
> Yahoo! Groups Links
>
>
>
>
>
>
Received on Tue May 04 13:21:00 2004