You make NPT threads inside the test hole ( you'd better not to call weep hole ) and plug with a screw. If you seal weld, then, you risk again letting welding gases to enter between the pad and the shell. Kind regards,

Hašim SAKARYA

-----Original Message-----
From: harihara.v ramanan [mailto:hramanan@yahoo.com] Sent: Wednesday, October 06, 2004 12:55 PM To: <a href="/group/PipingDesign/post?postID=ljU8QVV6McQZsmJcwTyYBYeBFU4e2JH7Ls-AcQVcFSh8uqCbtqbJuqRPw_kD_gDBWnmurEolsgDJI64rqqIPf5n8">PipingDesign@yahoogroups.com</a> Subject: [PipingDesign] Reinforcement Pad Weep hole Importance: Low

Friends

Weep holes are provided in nozzle reinforcement pads of branch connections in piping and nozzles in pressure vessels, tanks and heat exchangers to vent out the gases during welding. This weep hole is to be kept open during the hydrostatic test of the equipment. What is the practice during normal operation? Is this need to be seal welded, plugged or to be kept open? ANSI 31.3 and API 650 specify that this need to be kept open. As per one designers exchanger standard this need to be seal welded after hydrostatic test. If this is plug welded or plugged how can we find when it is leaking? If this is kept open is it possible that atmosphere get inbetween the shell and pad initiate corrosion? if it is plugged can the pad take the interanal pressure in case of shell failure.

Your view please,

Thanks

HVR



Do you Yahoo!?
Declare Yourself - Register online to vote today!
<a href="http://vote.yahoo.com">http://vote.yahoo.com</a> <<a href="http://vote.yahoo.com">http://vote.yahoo.com</a>>


PipingOffice - Excel Spreadsheets for Piping Calculations
<a href="http://www.pipingoffice.us/">http://www.pipingoffice.us/</a> <<a href="http://www.pipingoffice.us/">http://www.pipingoffice.us/</a>>


Main site: http://www.pipingdesign.com <http://www.pipingdesign.com>

Yahoo! Groups Sponsor

ADVERTISEMENT  
<<a href="http://us.ard.yahoo.com/SIG=1298cfvfr/M=295196.4901138.6071305.3001176/D=groups/S=1705083319:HM/EXP=1097142915/A=2128215/R=0/SIG=10se96mf6/*http://companion.yahoo.com">http://us.ard.yahoo.com/SIG=1298cfvfr/M=295196.4901138.6071305.3001176/D=groups\
/S=1705083319:HM/EXP=1097142915/A=2128215/R=0/SIG=10se96mf6/*http://companion.ya\ hoo.com</a>> click here   

<<a href="http://us.adserver.yahoo.com/l?M=295196.4901138.6071305.3001176/D=groups/S=:HM/A=2128215/rand=435529191">http://us.adserver.yahoo.com/l?M=295196.4901138.6071305.3001176/D=groups/S=:HM/\
A=2128215/rand=435529191</a>>


Yahoo! Groups Links

[Non-text portions of this message have been removed] Received on Wed Oct 06 07:49:00 2004

This archive was generated by hypermail 2.1.8 : Tue Mar 04 2008 - 11:40:36 EST