valves in Bitumen fouling

From: <Al>
Date: Mon Oct 18 2004 - 11:47:00 EDT

sajit
under the valve spec for Scouring coke it just says Valves Check, piston type axial flow, cl800 Sw horiz A182-F347H, B8m 347 SS/.Stel trim, cat1.

there are being used in hot service hence the 347,

WE've been using them for years in bitumen VTB and around the coker, but at higher temps.
i cant say for lower temp other than everything starts up an shuts down.

Also used in batch plants with 2 runs per week, starts up and cools down.

What you say is true , they can plug , but so can all valves in this service

What their spec. What does it have that s so different. We know ball valves are no good at all.
knife gates much better than wedge gates

cheers
This E-mail (Electronic Mail), its content and any files transmitted with it are intended solely for the addressee(s) and may be legally privileged and/or confidential. If you are not the intended recipient, please delete and contact the sender. It must not be disclosed to any person without our authority. If you are not the intended recipient, or a person responsible for delivering it to the intended recipient, you are not authorized to and must not disclose, copy, distribute, or retain this message or any part of it. Sender does not accept responsibility for changes made to this E-mail after it was sent.