Good day Paul,
Yes this K.O. Drums are on foundations...i am actually desinging pipe
routing for this large lines and to this, one of the requirement is
the computaions of stress analysis. i have not yet receive any
information from our client and i need to do this as early as
possible. maybe someoone have done this before just for checking the
result on our CAESAR II analysis...Thank you!
DATA on: (Allowable Reactions Loads) at nozzle of 48" & 54" K.O.
drums & Flare Stack.
Best Regards,
iaN pRete
- In PipingDesign@yahoogroups.com, Paul Bowers <pbowers@p...> wrote:
> > Does any one have a table for "Allowable Reaction Loads"
specifically
> > on K.O. Drums for 54" & 48" size Flare lines?
> > Your advice is greatly appreciated. THank you.
> >
> > Best Regards,
> > IaN pRETE
>
>
> If you have 54" and 48" flare lines (lines of that size deserve
special
> treatment) you should probably be consulting a competent engineer
that
> is experienced in this area.
>
> KO drums (are they sitting on foundations?), given that they are
> recieving relatively "low pressure" rejects from overpressure
devices,
> are a design specialty.
>
> You really need to discuss with a local competent engineer that is
> experienced with this. You don't want to fool around with piping of
this
> size.
>
> Maybe I should just put this into the "you should know better" file.
>
> Paul
Received on Sat Oct 23 02:12:00 2004