LPG Flashing

From: <gautam>
Date: Wed Jan 05 2005 - 22:48:00 EST

Dear Friends,
Can I have some information about LPG flashing? How and when does it occur and how does it affect the pipe flow networks
Gautam wayse

On Dec 28, 2004, at 11:37 PM, Umapathy, A wrote:

> For Static loading the Design factor of safety: 60%
of Yield stress is
> considered and for dynamic loading it would be 35%
  to have a life
> of 1 million cycles or more.

This is a bit over simplified becasue it depends greatly on the type of
construction and the service. The 60% number applies to AISC Code
design for working stress; oit's different for LRFD rules becasue the
design loads are factored upward. Neither figure applies to ASME piping
or pressure vessel code rules.

And just for cultural value, the safety factor is always greater than
1: it's the limiting stress or load divided by the maximum allowable
stress or load and it's not necessarily based on yield stress.

Christopher Wright P.E. |"They couldn't hit an elephant at
chrisw@skypoint.com | this distance" (last words of Gen.

...................................| John Sedgwick,
Spotsylvania 1864)
http://www.skypoint.com/~chrisw/

PipingOffice - Excel Spreadsheets for Piping Calculations
http://www.pipingoffice.us/

Main site: http://www.pipingdesign.com

Yahoo! Groups SponsorADVERTISEMENT



Yahoo! Groups Links

    To visit your group on the web, go to: http://groups.yahoo.com/group/PipingDesign/

    To unsubscribe from this group, send an email to: PipingDesign-unsubscribe@yahoogroups.com

    Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service.



Yahoo! India Matrimony: Find your life partner online Go to: http://yahoo.shaadi.com/india-matrimony Received on Wed Jan 05 22:48:00 2005

This archive was generated by hypermail 2.1.8 : Mon Oct 27 2008 - 20:24:06 EDT