Hi ebyc75
I would put the reducer at the pump suction and use the 2" bend
upstream. The reducer will help even out the flow entering the impeller.
Use the longest reducer you can find; one with a cone rather than a step
profile..
If there is no chance or air or gas accumulating at the suction (i.e.
well flooded suction) I would use a concentric reducer so that the
centreline of the flow leaving the reducer is at the centreline of the
impeller.
Donât forget to check your NPSHA and NPSHR.
Cheers
Steve
-----Original Message-----
From: ebyc75 [mailto:ebyc75@yahoo.com]
Sent: Sunday, March 20, 2005 2:44 AM
To: PipingDesign@yahoogroups.com
Subject: [PipingDesign] centrifugal pump suction
The inlet size of the pump is 1" and the suction line is 2" dia. Due to the space constrain can a long radius elbow be installed directly with the pump mating flange. If so should the eccentric reducer (2x1) should be before the elbow or in between the elbow and mating flange.
Thanks
http://www.pipingoffice.us/ =========================================Main site: http://www.pipingdesign.com