Re: Flex analysis

From: <Kuswadi@ikpt.com>
Date: Thu May 12 2005 - 21:01:00 EDT

for very long piping line, although the fluid temperature is at ambient temperature, we shall consider the solar radiation effect, the most severe condition, which could produce long thermal movement. 1. so piping engineer shall calculate such system at Solar radiation temperature, u can input 70degree C for calculation, or 40/50 centrigrade, depend on ur calculation requirement.
2. input for nozzle thermal movement if any 3. u can consider to make piping loop to absorb thermal movement

Best Regards

Muhammad Kuswadi
Piping Mechanical Engineer
PT IKPT
Engineering Procurement and Construction Jl. MT Haryono Kav 4-5
Jakarta 12820
Indonesia
Enjoy allways ur life

                     "gguerrat"
                     <gguerra_geci@att.        To:    
PipingDesign@yahoogroups.com
                     net.mx>                   cc:
                     Sent by:                  Subject:     [PipingDesign] Flex
analysis
                     PipingDesign@yahoo
                     groups.com


                     05/13/2005 05:39
                     AM
                     Please respond to
                     PipingDesign





Hi

Im related with the analysis of a carbon steel 8 in pipe for water ambient temperature instaled on exterior on suports with a lenght of 900 meters.

do any know if this type of system requieres, flexibility analysis for the lenght and for the temperature on sun conditions about 45 or 50 centigrades

Thanks



PipingOffice - Excel Spreadsheets for Piping Calculations http://www.pipingoffice.us/

Main site: http://www.pipingdesign.com

Yahoo! Groups Links Received on Thu May 12 21:01:00 2005