Gautam,
Caesar II analyses the piping system as a whole, while
Algor is meant for different stressed items (any
mechanical component, for that matter), in piping they
could be tees, wyes, stub-ins,trunnions,etc.
One is not the substitute for the other.
Good luck!
C. V. Gangadharan.
> hi guys
> is there some one here presently doing stress
> analyis of piping sytems
> using algor pipepak.
> what are the disadvantages of algor compared with
> ceaserII,
> ceapipe,triflex & other finite element analyis based
> pipe stress
> packages.
>
> Regards
> Gautam
>
>
>
>
>
This archive was generated by hypermail 2.1.8 : Mon Oct 27 2008 - 20:24:07 EDT