fyi I noticed some issues dealing with internal "beads" and conditions were
perhaps coincidentally discussed recently in an engineering forum thread at
<a href="http://www.eng-tips.com/viewthread.cfm?qid=124331&page=3,">http://www.eng-tips.com/viewthread.cfm?qid=124331&page=3,</a> as well as some
underground internal inspections for fusion joint conditions (and cracking etc.)
with cameras discussed in a past paper though now online at
<a href="http://www.pipe-line.com/archive/archive_99-09/99-09_ldc-romero.htm.">http://www.pipe-line.com/archive/archive_99-09/99-09_ldc-romero.htm.</a>
Randy Conner
-----Original Message-----
From: <a href="/group/PipingDesign/post?postID=DU36B-Cs7te-ndc2x1FVfzlwyMsRlvUu23BkE5Ymf_AhiGd5IbbKEK03uhe2WSDRaNhfMddXgDD1gbWboLnoCzVA">PipingDesign@yahoogroups.com</a>
[mailto:PipingDesign@yahoogroups.com]On Behalf Of elie altawil
Sent: Monday, July 18, 2005 7:50 AM
To: <a href="/group/PipingDesign/post?postID=DU36B-Cs7te-ndc2x1FVfzlwyMsRlvUu23BkE5Ymf_AhiGd5IbbKEK03uhe2WSDRaNhfMddXgDD1gbWboLnoCzVA">PipingDesign@yahoogroups.com</a>
Subject: Re: [PipingDesign] Hydrostatic Test for PE100 pipeline
Pick a pig (with a P) that will not hang by the internal beeds. Use a pig with an internal cavity and an electronic tracer for a long pipeline.
Take into account pressure due to static head of test medium even if you are using gas (air or nitrogen) for the hydrotest. Potential problems: If your test location is lower that the highest point in the pipeline, the highest point may not reach the minimum acceptable test pressure. Don't underestimate!
Under what ASME/? code are you testing the pipeline? B31.1/ .3/.4/.8 or AWWA?
Cheers, ET, PE.
Ashraf Farouk <ashraffrk@yahoo.com> wrote:
Please,
I would like to have your advice. If I'll test pipeline hydrostaticaly and this line is plastic pipes P.E100. Is there any specification that say I have to remove the internal beed in the butt fusion joints before pushing bigs in the line.
Thanks& Best Regards
[Non-text portions of this message have been removed]
To unsubscribe from this group, send an email to: <a href="/group/PipingDesign/post?postID=vPraTukfMPcbfCvo314OGLYwWadWDHEw5nY1mgO5Gg-gz8C3zHIF89eUGYhbN1HS1sPe9cnGvlD_9vo3f9Bc-oxwofdP1WzXFYaeWqo8Uqxk">PipingDesign-unsubscribe@yahoogroups.com</a>
Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service.
[Non-text portions of this message have been removed]
Yahoo! Groups Links
_________Confidentiality Notice_______________________This e-mail and any files transmitted with it is confidential and is intended solely for the use of the individual(s) or entity(ies) to whom this e-mail is addressed. If you are not the intended recipient or the person responsible for delivering the e-mail to the intended recipient, be advised that you have received this e-mail in error, and that any use, disclosure, dissemination, forwarding, printing, retention or copying of this e-mail is strictly prohibited. If you have received this e-mail in error, please immediately return this e-mail to the sender and delete the e-mail from your system. Thank you. Received on Mon Jul 18 13:34:00 2005