RE: Hydrostatic Test for PE100 pipeline

From: <elie>
Date: Tue Jul 19 2005 - 22:10:00 EDT

It is OK now.

"Conner, Randy" <RConner@acipco.com> wrote:link apparently to article from "Pipe Line & Gas Industry" at
http://www.pipe-line.com/archive/archive_99-09/99-09_ldc-romero.htm worked for me yesterday when I checked and today -- hope you can bring up

-----Original Message-----
From: PipingDesign@yahoogroups.com
[mailto:PipingDesign@yahoogroups.com]On Behalf Of elie altawil Sent: Tuesday, July 19, 2005 8:31 AM
To: PipingDesign@yahoogroups.com
Subject: RE: [PipingDesign] Hydrostatic Test for PE100 pipeline

The second web address you provided is dead.

> fyi I noticed some issues dealing with internal
> "beads" and conditions were perhaps coincidentally
> discussed recently in an engineering forum thread at
>
>

http://www.eng-tips.com/viewthread.cfm?qid=124331&page=3,
> as well as some underground internal inspections for
> fusion joint conditions (and cracking etc.) with
> cameras discussed in a past paper though now online
> at
>

http://www.pipe-line.com/archive/archive_99-09/99-09_ldc-romero.htm.
> Randy Conner
>
> -----Original Message-----
> From: PipingDesign@yahoogroups.com
> [mailto:PipingDesign@yahoogroups.com]On Behalf Of
> elie altawil
> Sent: Monday, July 18, 2005 7:50 AM
> To: PipingDesign@yahoogroups.com
> Subject: Re: [PipingDesign] Hydrostatic Test for
> PE100 pipeline
>
>
>
> Pick a pig (with a P) that will not hang by the
> internal beeds. Use a pig with an internal cavity
> and an electronic tracer for a long pipeline.
> Take into account pressure due to static head of
> test medium even if you are using gas (air or
> nitrogen) for the hydrotest. Potential problems: If
> your test location is lower that the highest point
> in the pipeline, the highest point may not reach the
> minimum acceptable test pressure. Don't
> underestimate!
> Under what ASME/? code are you testing the
> pipeline? B31.1/ .3/.4/.8 or AWWA?
>
> Cheers, ET, PE.
>
>
>
> Ashraf Farouk <ashraffrk@yahoo.com> wrote:
>
> Please,
>
> I would like to have your advice. If I'll test
> pipeline hydrostaticaly and this line is plastic
> pipes P.E100. Is there any specification that say I
> have to remove the internal beed in the butt fusion
> joints before pushing bigs in the line.
>
> Thanks& Best Regards
>
>
>
> ---------------------------------
> Start your day with Yahoo! - make it your home page
>
> [Non-text portions of this message have been
> removed]
>
>
>
> =========================================
> PipingOffice - Excel Spreadsheets for Piping
> Calculations
> http://www.pipingoffice.us/
> =========================================
> Main site: http://www.pipingdesign.com
>
>
>
>
> ---------------------------------
> YAHOO! GROUPS LINKS
>
>
> Visit your group "PipingDesign" on the web.
>
> To unsubscribe from this group, send an email
> to:
> PipingDesign-unsubscribe@yahoogroups.com
>
> Your use of Yahoo! Groups is subject to the
> Yahoo! Terms of Service.
>
>
> ---------------------------------
>
>
>
>
> __________________________________________________
> Do You Yahoo!?
> Tired of spam? Yahoo! Mail has the best spam
> protection around
> http://mail.yahoo.com
>
> [Non-text portions of this message have been
> removed]
>
>
>
> =========================================
> PipingOffice - Excel Spreadsheets for Piping
> Calculations
> http://www.pipingoffice.us/
> =========================================
> Main site: http://www.pipingdesign.com
>
> Yahoo! Groups Links
>
>
>
>
>
>
> _________Confidentiality
> Notice_______________________
> This e-mail and any files transmitted with it is
> confidential and is intended solely for the use of
> the individual(s) or entity(ies) to whom this e-mail
> is addressed. If you are not the intended recipient
>
> or the person responsible for delivering the e-mail
> to the intended recipient, be advised that you have
> received this e-mail in error, and that any use,
> disclosure, dissemination, forwarding, printing,
> retention or copying of this e-mail is strictly
> prohibited. If you have received this e-mail in
> error, please immediately return this e-mail to
> the sender and delete the e-mail from your system.
> Thank you.
>
>



Yahoo! Mail
Stay connected, organized, and protected. Take the tour: http://tour.mail.yahoo.com/mailtour.html

PipingOffice - Excel Spreadsheets for Piping Calculations http://www.pipingoffice.us/

Main site: http://www.pipingdesign.com

Yahoo! Groups Links

_________Confidentiality Notice_______________________
This e-mail and any files transmitted with it is confidential and is intended solely for the use of the individual(s) or entity(ies) to whom this e-mail is addressed. If you are not the intended recipient or the person responsible for delivering the e-mail to the intended recipient, be advised that you have received this e-mail in error, and that any use, disclosure, dissemination, forwarding, printing, retention or copying of this e-mail is strictly prohibited. If you have received this e-mail in error, please immediately return this e-mail to the sender and delete the e-mail from your system. Thank you.

PipingOffice - Excel Spreadsheets for Piping Calculations http://www.pipingoffice.us/

Main site: http://www.pipingdesign.com

YAHOO! GROUPS LINKS      Visit your group "PipingDesign" on the web.

     To unsubscribe from this group, send an email to:   PipingDesign-unsubscribe@yahoogroups.com

     Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service.




Do You Yahoo!?
Tired of spam? Yahoo! Mail has the best spam protection around http://mail.yahoo.com

[Non-text portions of this message have been removed] Received on Tue Jul 19 22:10:00 2005

This archive was generated by hypermail 2.1.8 : Mon Oct 27 2008 - 20:24:08 EDT