FW: [PipingDesign] Comparing buttweld and socketweld joints

From: <Detailed>
Date: Mon Jul 25 2005 - 02:28:00 EDT

AS PER IBR BUTT WELDED JOINT ARE PREFERABLE AT HIGH PRESSURE ......... PRESSURE MORE THEN 1550# (BAR)WITH 100% WORKING EFFICIENCY UDAY DAVE
CAD SECTION
TATA CHEMICALS LIMITED
MITHAPUR
> -----Original Message-----
> From: jonnalagadda.narasimham@linde-le.com
> [SMTP:jonnalagadda.narasimham@linde-le.com]
> Sent: Monday, July 25, 2005 11:14 AM
> To: PipingDesign@yahoogroups.com
> Subject: Re: [PipingDesign] Comparing buttweld and socketweld joints
>
> Hello,
>
> As per my experience , Butt welded joints are preferable at high
> pressure....pressures more than 100 bar.
>
> Narasimham
>
>
>
>
>
> "M.Bakhshi" <M.Bakhshi@namvaran.com>
> Sent by: PipingDesign@yahoogroups.com
> 25/07/2005 10:18
> Please respond to PipingDesign
>
> To: <PipingDesign@yahoogroups.com>
> cc: (bcc: Jonnalagadda
> Narasimham/Internal/Baroda/LPTI/Linde-VA)
> Subject: [PipingDesign] Comparing buttweld and socketweld
> joints
>
>
>
> Hi all,
>
> Has anybody seen any reference about comparing between socket weld and
> butt-weld joints?
> Which one is more safe in high pressure services? and what is the reason
> to
> select each of them?
> And also which one has more strength ?
>
> Tx,
> Mahnoush
>
>
>
>
>
> ------------------------ CONFIDENTIALITY DISCLAIMER
> -----------------------
>
> This message may contain confidential information and must not be
> copied, disclosed or used by anybody other than the intended recipient.
> If you have received this message in error, please notify us by e-mail
> (admin@namvaran.com) and then delete the message, enclodsed
> documents and any other relevant copies..
>
> Thank you for your assistance.
> Namvaran Consulting Engineers and Managers
> No. 7, Khorasani Str., Gheytarieh Ave., Tehran 19389 - Iran
> Telephone: +98 21 2231620, Fax: +98 21 2231597
>
>
>
>
>
>
>
> =========================================
> PipingOffice - Excel Spreadsheets for Piping Calculations
> http://www.pipingoffice.us/
> =========================================
> Main site: http://www.pipingdesign.com
>
> Yahoo! Groups Links
>
>
>
>
>
>
>
>
>
> [Non-text portions of this message have been removed]
>
>
>
>
>
> =========================================
> PipingOffice - Excel Spreadsheets for Piping Calculations
> http://www.pipingoffice.us/
> =========================================
> Main site: http://www.pipingdesign.com
>
> Yahoo! Groups Links
>
>
>
>
>
>

This message is intended only for the use of the person in his official capacity to whom it is addressed and for the intended purpose only. The contents of this email may contain confidential, proprietary, legally privileged and protected information. It should not be used by anyone who is not the original intended recipient. If you are not the intended recipient, destroy all copies of the original message and any attachments thereto. It is hereby notified that any review, dissemination, distribution, duplication, printing or copying of this communication is strictly prohibited. Tata Chemicals Limited declares that it is not within its prerogative and control to ensure guarantee on the integrity of/over the contents of the information contained in e-mail transmissions and that any views expressed in this message are those of the individual sender and no binding nature of the message shall be implied or assumed on Tata Chemicals Limited unless the sender does so expressly with due authorization of Tata Chemicals Limited. Tata Chemicals Limited has taken due care and caution to make this E-mail message virus free that might affect any system into which it is received/ opened. However, it is the responsibility of the recipient to check for any virus/ defects and Tata Chemicals Limited shall not be responsible for any loss or damage arising in any way from its use. Received on Mon Jul 25 02:28:00 2005