Re: Unsustained Loading -Flange Pressure Rating

From: <Christopher>
Date: Tue Aug 16 2005 - 11:20:00 EDT


On Aug 16, 2005, at 7:41 AM, Saha, Tanmoy wrote:

> Usually surge loads are quite high and flanges cannot be designed for
> that due to economic reason.

So what do you tell your customer when you're standing over the ruins and he asks you why the hell his system came apart?

Christopher Wright P.E. |"They couldn't hit an elephant at <a href="/group/PipingDesign/post?postID=nKx9eEV2FQyMN8eZOzFROD0BWzZyEw09oylJdaPcQ4Z4L_H2SyV2yv0c6p7x0XJ8oRtVaEFp-spR">chrisw@skypoint.com</a> | this distance" (last words of Gen.

.......................................| John Sedgwick, Spotsylvania
1864)
<a href="http://www.skypoint.com/~chrisw/">http://www.skypoint.com/~chrisw/</a> Received on Tue Aug 16 11:20:00 2005

This archive was generated by hypermail 2.1.8 : Tue Mar 04 2008 - 11:40:43 EST