Sure some of the piping component can be re-used but in most cases I wont
especially for the piping components that have been exposed in severe
service or showed some sign of deterioration. Take the example of a pipe
header in which the nozzle has to be replaced. The replacement nozzle was a
leftover material from a previous job (say with an olet fitting). Size and
material OK and all it needs is a lilltle weld prep. Fitup the "salvaged"
material to the pipe and after a short period of operation, started leaking.
Get worse by the day and after a week left with no option but to shut down
the unit. Olet require a lot of weld deposit which may "cook" the existing
process piping. Get worse if pwht is needed and worse if the remaining
thickness is at its lowest minimum.
[Non-text portions of this message have been removed] Received on Sat Sep 03 08:45:00 2005
This archive was generated by hypermail 2.1.8 : Tue Mar 04 2008 - 11:40:43 EST