On Sep 19, 2005, at 10:26 PM, elie altawil wrote:
> The maximum allowable
> pressuretemperature ratings for these flanges range
> from 50 psi to 200 psi (refer to the standard for
> specific ratings).
B16.1 CL 125 ratings apply to cast iron only, not SA-181. Ratings for
SA-181 established by ASME Code rules should be much different.
Christopher Wright P.E. |"They couldn't hit an elephant at
<a href="/group/PipingDesign/post?postID=FKUG8ia0ywHyS1tG-ejaFxZncvtaMb76uxZB-IZG78H6p2bFQTF4UK5zpeheLepzVq-d0rYZ9ebOrak">chrisw@skypoint.com</a> | this distance" (last words of Gen.
.......................................| John Sedgwick, Spotsylvania1864)