IT IS POSSIBLE.
AS THE HYDROTEST IS OCCATIONAL LOAD WE CAN CONSIDER
THE ALLOWABLE STRESS BY 33% FACTOR MORE BUT SOMEWHERE
THERE IS POSSIBILTY THAT WE WILL HAVE THE LEAKAGE IN
FLANGE DURING THE TEST .
SO THE GASKET OF THAT FLANGE SHALL BE CHANGED.
> Hello,
>
> The MOP of the system we are working on is 1305 psig
> which will be 90 barg. The flanges are class 600.
> The test pressure of this system will be around 1827
> psig or 126 barg. Is it possible to test this system
> with this test pressure while the class is 600#?
>
> Thanks
>
>
> ---------------------------------