When the discharge line is full you can start a pump with the valve open.
When the line is empty you should start with the discharge valve closed
otherwise the flow at startup is too high and there is also a risk of
waterhammer the moment the line is completely filled.
Pumps in parallel operation are usually installed with a check-valves at the discharge side. When there are no check-valves an automatic operating valve is used to prevent pumping fluid from one pump through the other pump.
Erik
Van: <a href="/group/PipingDesign/post?postID=Z8RLfzNbtJ9fq9w13AO6uPd-5LuN1gLnfIXq56FYrHlJJbTJKNDQrjDfLhDweBuf8VI3v0BXQ8AQdwg17AcfcWYP0Xc">PipingDesign@yahoogroups.com</a> [mailto:<a href="/group/PipingDesign/post?postID=Z8RLfzNbtJ9fq9w13AO6uPd-5LuN1gLnfIXq56FYrHlJJbTJKNDQrjDfLhDweBuf8VI3v0BXQ8AQdwg17AcfcWYP0Xc">PipingDesign@yahoogroups.com</a>]
Namens VIJAYAN PULIKKATH
Verzonden: Monday, October 17, 2005 7:21 AM
Aan: <a href="/group/PipingDesign/post?postID=Z8RLfzNbtJ9fq9w13AO6uPd-5LuN1gLnfIXq56FYrHlJJbTJKNDQrjDfLhDweBuf8VI3v0BXQ8AQdwg17AcfcWYP0Xc">PipingDesign@yahoogroups.com</a>
Onderwerp: [PipingDesign] discharge valve of pumps
From: Vijayan Pulikkath
Location: Consultants, Chennai, India
Asst Design Engr
valve open
valve closed
2) Reason?
3) Is it normal to have an interlock for pump start/stop with the discharge valve when they are operating in parallel and on auto standby? Is it essential?
Vijayan
[Non-text portions of this message have been removed]
SPONSORED LINKS
Mechanical
<<a href="http://groups.yahoo.com/gads?t=ms&k=Mechanical+engineering+jobs&w1=Mechanic">http://groups.yahoo.com/gads?t=ms&k=Mechanical+engineering+jobs&w1=Mechanic</a>
al+engineering+jobs&w2=Cad+drafter&w3=Process+piping&w4=Mechanical&c=4&s=86&
.sig=eJlTt13AisXBJmj5Yd3gpA> engineering jobs
Cad
<<a href="http://groups.yahoo.com/gads?t=ms&k=Cad+drafter&w1=Mechanical+engineering+j">http://groups.yahoo.com/gads?t=ms&k=Cad+drafter&w1=Mechanical+engineering+j</a>
obs&w2=Cad+drafter&w3=Process+piping&w4=Mechanical&c=4&s=86&.sig=vvtOzHLmT18
e_QbAWxTkqw> drafter
Process
<<a href="http://groups.yahoo.com/gads?t=ms&k=Process+piping&w1=Mechanical+engineerin">http://groups.yahoo.com/gads?t=ms&k=Process+piping&w1=Mechanical+engineerin</a>
g+jobs&w2=Cad+drafter&w3=Process+piping&w4=Mechanical&c=4&s=86&.sig=I5RWrbfa
QuXyAXwIwxmu0g> piping
Mechanical
<<a href="http://groups.yahoo.com/gads?t=ms&k=Mechanical&w1=Mechanical+engineering+jo">http://groups.yahoo.com/gads?t=ms&k=Mechanical&w1=Mechanical+engineering+jo</a>
bs&w2=Cad+drafter&w3=Process+piping&w4=Mechanical&c=4&s=86&.sig=7WtmMVWyA0yY
VZsyGxvDoA>
YAHOO! GROUPS LINKS
[Non-text portions of this message have been removed] Received on Mon Oct 17 14:21:00 2005
This archive was generated by hypermail 2.1.8 : Tue Mar 04 2008 - 11:40:45 EST